C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery

Product Details
Customization: Available
Type: Lead-Acid Batteries
Usage: Car, UPS, Electric Power, Electric Bicycle
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Address
Room 701, Office Building, Zhonglv Plaza, No. 1 Tenglong Road, Dali Town, Nanhai District, ...
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DDP, DAP, CIP
Terms of Payment
LC, T/T, D/P, PayPal, Western Union
  • C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery
  • C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery
  • C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery
  • C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery
  • C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery
  • C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery
Find Similar Products

Basic Info.

Model NO.
LBTY 12V 12-200 LBT
Nominal Voltage
12V
Discharge Rate
High Discharge Rate
Shape
Cylindrical Battery
Electrolyte
Acid
Installation
Fixed
Rechargeable
Chargeable
Capacity
200ah
Weight
64.3kgs
The Number of Individual Cells in Each B
6
Operating Temperature Range
Discharge: -20°c to 50°c, Charging: -20
Recommended Operating Temperature Range
23°c to 27°c
Floating Charge Voltage
When The Average Temperature Is 25°c, 13.62 Vd
Recommended Maximum Charging Current
C/5A (1/5th of The Current of The 20-Hour Rate Cap
Transport Package
Carton
Specification
525*239*227mm
Trademark
LBT
Origin
China
Production Capacity
100000

Product Description

Product Introduction
C&D 12V LBTY Series Valve Regulated Lead Acid Battery

For Standby Power Applications12V 7 Ah-250Ah

Applications

·Telecommunications

·General Purpose Applications

·Uninterrupted Power Supply (UPS)

·Other Float Applications


Features

·Design life:10 years(>26Ah) 5 years(≤26Ah)

·Not restrictedfor air transport-Complies with IATA/ICAOSpecial Provision A67.

·Flame-aresting one-way pressure-rlief vent for safety and long life

·Absorbent Gass Mat(AGM)technology for deffdient gas recombination ofup to 99%andfreedom fromelectrolyte maintenance

·Not restricted for surface transport-dassified as non-hazardous material as related to DOT-CFRTitle49 parts 171-189

·Not restricted for water transport-classifed as non-hazardousmaterial per IMDGAmendment 27

·Multicelldesign for economy of installation and maintenance

·Manufactured in accordance with IS09001,1SO 14001,and IS045001

·Low Calaum alloy grid for minimal gassing and ease of recycling

·Designed to be compliant with international standard IEC 60896-21/22

·Flame retardant polypropylene case and cover
C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid BatteryC&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery

C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery
C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery



Specifications

Model V Capacity/Ah
(C20,1.75V@25ºC)
Dimensions(mm) Weight/Kg Terminal Type(Bolt)
L W H TH
C&D 12-7 LBT 12  151  65  94  100  2.2  Faston Tab 250
C&D 12-9 LBT 12  151  65  94  100  2.4  Faston Tab 250
C&D 12-12 LBT 12  12  151  98  95  101  3.3  Faston Tab 250
C&D 12-18 LBT 12  18  181  76  163  166  5.5  M5
C&D 12-26 LBT 12  26  166  175  123  125  7.9  M5
C&D 12-38 LBT 12  38  197  166  166  166  12.0  M6
C&D 12-50 LBT 12  50  262  168  175  175  15.5  M6
C&D 12-65 LBT 12  65  348  167  180  180  19.0  M6
C&D 12-80 LBT 12  80  258  168  213  213  21.5  M8
C&D 12-100 LBT 12  100  330  175  221  221  28.0  M8
C&D 12-110LBT 12  110  329  175  221  221  30.5  M8
C&D 12-120 LBT 12  120  408  177  224  224  32.0  M8
C&D 12-150LBT 12  150  483  170  240  240  39.5  M8
C&D 12-200 LBT 12  200  520  239  223  223  56.0  M8
C&D 12-230 LBT 12  230  549  259  233  233  63.0  M8
C&D 12-240LBT 12  250  549  259  233  233  66.0  M8
Operating Temperature Range
with temperature compensation
-20ºC~50ºC
Recommended Operating Temperature Range 23ºC-27ºC
Floating Charging Voltage 13.62VDC/unit Average at 77°F(25ºC)
Recommended Maximum Charging Current Limit 0.2CA@20hr rate
Equalization and Cycle Service Charging Voltage 14.4VDC/unit Average at 77°F(25ºC)
Maximum AC Ripple (Charger) 0.5%RMS or 1.5%P-P of float charge voltage recommended for best results.Maximum voltage
allowed=1.4%RMS(4%P-P).Maximum current allowed=C/20A RMS.
Self Discharge Batteries may be stored for up to 4 months at 77°F(25ºC)and then a freshening charge is
required.For higher temperatures the time interval will be shorter.
Accessories (Optional) Inter unit connectors,racks and cabinet systems are available.

C&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid BatteryC&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid BatteryC&D Liberty UPS 12V 12-200lbt VRLA Sealed Lead-Acid Battery

FAQ:

1. What is the MOQ ? 
1 set. 
 
2.Can you provide samples?  
Yes.
 
3. Is OEM/ODM available? 
Yes, it is! You can put on your own LOGO.
 
4. What is the Terms of Payment? 
T/T,  LC, PayPal, Western Union.
 
5. How is the delivery time ?   
It depends your order quantity and it normally takes 5-20 days . 
 
6. How long is the service life ? 
It is 20-30 years.  
 
You're welcomed to contact us for any questions.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now