Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner

Product Details
Customization: Available
Type: Cabinet Air Conditioner
Air Tube Material: Galvanized Sheet
Still deciding? Get samples of $ !
Request Sample
Gold Member Since 2025

Suppliers with verified business licenses

Registered Capital
1000000 RMB
  • Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
  • Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
  • Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
  • Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
  • Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
  • Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
Find Similar Products
  • Overview
  • Specification
  • FAQ
Overview

Basic Info.

Model NO.
NetCol8000- A045U
Corrosion Durability
Ultrahigh
Operating Voltage
380/400 VAC
Noise Level
Low
Application Fields
Data Center, Laboratory Air Conditioner
Mounting
Floor Standing
Lifetime
10~15 years
Certification
RoHS, UR, ISO, CE
Condition
New
Total Cooling Capacity
45kw
Sensible Capacity
45kw
Air Flow
11250m3 /H
Cooling Agent
R410A
Reheating Amount
6.0kw
Humidification Amount
4.5kg/H
Transport Package
Wooden Box
Specification
2000× 900× 900
Origin
China
Production Capacity
100000

Product Description

Product Introduction
The NetCol8000-A series belongs to the room-level air-cooled intelligent temperature control products. It consists of an indoor unit and an outdoor unit to form a complete refrigeration system. It adopts a fully variable frequency design and supports both top and bottom air supply, meeting the cooling requirements of different computer rooms. It is usually deployed around the computer room and installed against the wall, providing an efficient, reliable and simple cooling solution for small and medium-sized low-density computer rooms, and contributing to the creation of the next-generation green data center.
Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
Application scenarios
• Computer rooms and data centers
• UPS and battery rooms
• High-precision laboratories and testing centers
• Industrial precision control rooms and medium-large switch rooms
Value and Characteristics
Simple
• 7-inch true-color touch screen, displaying key information in real time
• Fan rotates downward, no need for lifting tools, saving 70% of installation time 
Green
• Full variable-frequency architecture, DC variable-frequency compressor, on-demand cooling, up to 30% energy savings compared to fixed-frequency systems
• "Zero" power consumption humidification membrane
• iCooling intelligent optimization algorithm, energy efficiency can be improved by up to 8% with the same hardware conditions
Intelligence
• The AI algorithm detects the refrigerant content. When the refrigerant is insufficient, it automatically alerts, preventing the deterioration of the unit's performance or even its shutdown.
• Self-diagnosis of faults, rapid operation and maintenance
Safety
 • Stable dehumidification even at a load of over 10%. Avoiding condensation in the computer room due to excessively high humidity.
• Automatic dual-power supply switching
Specification
total cooling capacity:
45 kW
Apparent cooling capacity:
45 kW
Air volume:
11,250m3 /h
Refrigerant:
R410A
Humidification capacity:
6.0 kg/h
Height × width × depth (mm) :
2000×900×900
Net weight (kg) :
355
Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
Hw CE Certification Data Center Air-Cooled Upflow Air Netcol8000 Precision Air Conditioner
FAQ

1. What is the MOQ ? 
1 set. 
 
2.Can you provide samples?  
Yes, you just pay for shipping.
 
3. Is OEM/ODM available? 
Yes, it is! You can put on your own LOGO.
 
4. What is the Terms of Payment? 
T/T,  LC, PayPal, Western Union.
 
5. How is the delivery time ?   
It depends your order quantity and it normally takes 5-20 days . 
 
6. How long is the service life ? 
It is 20-30 years.  
 
You're welcomed to contact us for any questions.